ESWL service and training

A premium lithotripter deserves specialist care.

Preventive maintenance, high-voltage and sub-assembly repair for ESWL systems.
Technician training and on-demand service, wherever your system treats patients.
Specializing in Storz Modulith lithotripters.

Save the surprises for the stones.

Ma ≈ 1 Where it started: a water droplet, an airfoil, and the speed of sound.

Why a specialist

Built to last. Worth protecting.

A Storz Modulith is a long-term commitment. The programs that run one keep it for years, and the physicians who depend on it expect the same performance on the last patient of the day as the first.

Our shared goals: maximum uptime, patient safety you can document, and an investment that stays in top condition.

Services

Six ways to keep ESWL running.

Training

Operator and service training

Hands-on ESWL training for clinical staff, technologists and in-house biomedical engineers, with deep coverage of the Storz Modulith SLX-F2.

  • System operation and patient setup
  • Daily checks and first-line troubleshooting
  • Training records and certificates for your files
Preventive maintenance

Scheduled PM to procedure

ESWL preventive maintenance performed to manufacturer procedures, measured with calibrated, traceable test equipment and documented as found and as left.

  • Shockwave source and coupling
  • Imaging and alignment verification
  • Safety and performance checks
Repair

High-voltage and sub-assembly repair

Diagnosis and repair of the PCCU, high-voltage circuits and critical sub-assemblies that take a system out of service, often at a fraction of the cost of a replacement assembly.

  • PCCU and high-voltage fault isolation to the component
  • Repair, replacement and functional verification
  • Complete service reporting with root cause analysis
Technical writing

Procedures and protocols, written to standard

Audit-ready service procedures, PM protocols, test plans and training materials, developed to the applicable regulations and standards by an engineer who has written them for FDA- and CSA-regulated work. Every document is original work.

  • Service and PM procedures, checklists and work instructions
  • Test protocols with acceptance criteria tied to manufacturer's specifications
  • Training curricula, competency records and quality documentation
Remote support

Expert remote support, by the block

Prepaid blocks of remote technical support for in-house biomedical teams and service organizations. Get answers on troubleshooting, procedures and parts from someone who knows the system, without waiting for a site visit.

  • Phone, video and email support
  • Hours drawn down only as used
  • A usage statement with every draw-down
Data analytics

Service data that answers questions

Turn service records, error logs and treatment volumes into reporting that shows where uptime is lost, which failures repeat, and whether PM is preventing them.

  • Uptime, failure and repeat-fault trends by system or fleet
  • PM effectiveness and parts-usage analysis
  • Clear reports for budget, capital and service-contract decisions
  • Service record and quote-to-cash setup for small service organizations

What you get

Documented to the number.

Every PM follows the manufacturer's procedure and ends with a checklist of measured values, recorded as found and as left against manufacturer's specifications. Every repair ends with a service report: the fault, the fix, the parts, and the calibrated test equipment used to prove it. Every training ends with a signed record for each attendee.

Work performed to manufacturer's procedures and specifications. Electrical safety testing per IEC 62353. X-ray components maintained to 21 CFR 1020. Test equipment calibrated and traceable to NIST.

quality with a little q in the work.
Quality with a big Q in the paperwork.

ΩkVmA±0.5%10.00µsHzVΩΣ√πMΩdB

For system owners

More treatment days, documented safety, lower repair cost.

Hospitals and mobile lithotripsy operators carry the cost of every day an SLX-F2 is down. The most expensive repairs come from guessing: parts swapped until the fault goes away, and failures that return because the root cause was never found. Service here starts with understanding why it failed.

UptimeScheduled PM and fast fault isolation keep treatment days on the calendar.
SafetyWork performed to procedure and verified with calibrated, traceable test equipment.
CostHigh-voltage circuits repaired at the component level instead of replacing whole assemblies.
ExpertiseEvery SLX-F2 generation, 20+ years in medical device field service.

Contact

Keep your ESWL program treating patients.

Send the system serial number, the site and the issue: a PM that is due, a training need, or a fault you are chasing. Replies within one business day.

[email protected]